PowerExchange for CDC and Mainframe
- PowerExchange for CDC and Mainframe 10.4.1
- All Products
DUMPDIAG [database keywords] [CCATALOG=table_name] BVTS=begin_VTS[EVTS=end_VTS] DIR=dump_directory[REPLACE={N|Y}] ;
Parameter | Description |
---|---|
CCATALOG | Name of the capture catalog table. |
BVTS | Required. The starting timestamp for the diagnostics file in the format YYYY -MM -DD -HH .MI .SS .SSSSSS . The year, month and day are required. BVTS values are always specified in GMT (Greenwich Mean Time). |
EVTS | The ending timestamp for the diagnostics file in the format YYYY -MM -DD -HH .MI .SS .SSSSSS . The year, month and day are required. EVTS values are always specified in GMT (Greenwich Mean Time). |
DIR | Required. The directory where the diagnostics file is written. The file name is “ccatdmp. database_name .capture_catalog_name .sql“ and cannot be changed. |
REPLACE | Indicates whether to overwrite existing files. Specify Y to overwrite existing files. |
PWX-20512 Producing file 'dtst20061221\ccatdmp.cap14.partcaptst.sql' PWX-20512 Producing file 'dtst20061221\dbconfig.txt' PWX-20512 Producing file 'dtst20061221\p0.logdmp' PWX-20540 Begin LSN 0000042B3EBC0000 selected for BVTS value PWX-20519 End of UDB log file reached PWX-20512 Producing file 'dtst20061221\p1.logdmp' PWX-20540 Begin LSN 00000768C1040000 selected for BVTS value PWX-20519 End of UDB log file reached PWX-20512 Producing file 'dtst20061221\p20.logdmp' PWX-20540 Begin LSN 0000046B76C10000 selected for BVTS value PWX-20519 End of UDB log file reached PWX-20506 Command DUMPDIAG complete