PWX- 14517

PWX-
14517

Configuration file parameters LOGPATH and TRACING/PFX will cause tracing file names
nnn
bytes too long.
PowerExchange creates the alternative log files names by using the LOGPATH parameter, and the PFX parameter of the TRACING statement, in the DBMOVER configuration file. PowerExchange has detected that these values result in a file name that is too long for the operating system on which it is running.
PowerExchange writes all messages to the default PowerExchange log file and does not use the alternative log.
Change the value of the LOGPATH parameter, and the PFX parameter of the TRACING statement, so that the generated file names meet the requirements of your operating system.