failed because the listener did not accept the connection.
A client application attempt to establish an SSL secure connection to a PowerExchange Listener on z/OS failed because the remote peer where the PowerExchange Listener runs did not accept the connection.
The task ends.
Perform the following actions to troubleshoot the connection error:
Verify that the PowerExchange Listener is running on the z/OS node.
Verify that the PowerExchange Listener and AT-TLS rules are properly configured on the z/OS node.
Check the TCP/IP and AT-TLS logs to verify that AT-TLS intercepted the TCP/IP request, removed the TLS packaging, and passed the request to the PowerExchange Listener. The message PWX-31062 shows the node where the logs reside.
Check the PowerExchange Listener logs to look for any packets received from the client application IP address.
If you need assistance, contact Informatica Global Customer Support.