Table of Contents

Search

  1. Preface
  2. Change Data Capture Introduction
  3. PowerExchange Listener
  4. PowerExchange Condense
  5. DB2 for i5/OS Change Data Capture
  6. Remote Logging of Data
  7. Introduction to Change Data Extraction
  8. Extracting Change Data
  9. Monitoring CDC Sessions
  10. Managing Change Data Extractions
  11. Tuning CDC Sessions
  12. Appendix A: DTL__CAPXTIMESTAMP Time Stamps

CDC Guide for i5/OS

CDC Guide for i5/OS

Displaying PowerExchange Condense Status

Displaying PowerExchange Condense Status

To display the current status of the Condense Controller and each subtask for a PowerExchange Condense job, issue the DISPLAY STATUS command.
Use the following syntax to issue the DISPLAY STATUS command:
SNDPWXCMD CMDHDLRLIB(
condlib
) DTLCMD(DISPLAY) DISPLAYOPT(STATUS)
The
condlib
variable is the name of the library that contains the condense files, which you specified in the COND_DIR parameter of the CAPTPARM configuration file.
Alternatively, issue a pwxcmd displaystatus command from a Linux, UNIX, or Windows system to a PowerExchange Condense process running on an
i5/OS
system.