PowerExchange for CDC and Mainframe
- PowerExchange for CDC and Mainframe 10.5.4
- All Products
Component
| Result If the Component Fails
| Recovery
|
---|---|---|
ECCR
| Capture for that ECCR is interrupted.
| Restart the ECCR.
|
PowerExchange Agent
| Capture registrations cannot be verified.
| Restart the PowerExchange Agent.
|
PowerExchange Condense
| No new CDC data condensed.
| Restart PowerExchange Condense.
|
PowerExchange Logger
| The ECCRs that reside on the same system as the failed PowerExchange Logger also fail.
| Restart the PowerExchange Logger and then the ECCRs.
|
PowerExchange Listener
| The member Loggers and the Post-Log Merge job continue to run. Real-time extraction CDC sessions fail.
| Restart the PowerExchange Listener and then restart the failed CDC sessions.
|
Post-Log Merge job
| The member Loggers continue to run but real-time extraction CDC sessions fail.
| Restart the Post-Log Merge job and then restart the failed CDC sessions.
|