PowerExchange for CDC and Mainframe
- PowerExchange for CDC and Mainframe 10.5.9
- All Products
// JOB //READER EXEC PGM=EDMLUCTR //STEPLIB DD DISP=SHR,DSN=hlq.LOAD //ERDS01 DD DISP=SHR,DSN=your.ERDS01 //EDMPARMS DD DISP=SHR,DSN=your.USERLIB //SYSIN DD * -SEL LOGRBA=000000002D7C0000 CHANGE-DETAIL -SEL RECORDS=100 /*
EDMMSG log start PWXEDM175000I Log Scan/Print Utility initializing Echo of input from SYSIN.............. ----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8 -SEL LOGRBA=000000002D7C0000 CHANGE-DETAIL -SEL RECORDS=100 End of input from SYSIN.............. PWXEDM175005I Begin data transfer at 000000002D7C0000 PWXEDM172146I Reader UTILITY ERDS01 reading at RBA 000000001000 in SYS00001-EDMTEST.V900.V2.SB2L.LG1.D2025093.T2352283 Beg-pkt EDP-UOW=SB2L 000000002D7C00000000 LogRBA=000000002D7C0000 ECCR-UOW=SB2IMSEC SB2IMSEC E2C2F2C9D4E2C5C3 0000000000000015 Timestamp-21:39:24.302468 Date-04/03/2025 Chg-rec EDP-UOW=SB2L 000000002D7C00000000 LogRBA=000000002EF60000 ECCR-UOW=SB2IMSEC E2C2F2C9D4E2C5C3 0000000000000015 Source=VSM Func=ISRT Srcname=IMLEDMAls2aaseg100000 Timestamp-21:39:24.302468 Date-04/03/2025 0000 00000003 00000014 000000B4 000000B4 0010 000001B8 00A00101 C3E56008 00000000 CV- 0020 E2E30000 00000000 00000000 00160000 ST 0030 00000000 00000000 8000E0AF 6E338588 \ >eh 0040 4062C9D4 D3C5C4D4 C193A2F2 8181A285 IMLEDMAls2aase 0050 87F1F0F0 F0F0F040 40404040 40404040 g100000 0060 40404040 4040E2C2 F2D34040 00000000 SB2L 0070 2D7C0000 00000000 00002EF6 00000000 @ 6 0080 C4E3D300 00000001 E2C2F2C9 D4E2C5C3 DTL SB2IMSEC 0090 00000000 00000015 00000000 00000000 00A0 00000000 00000100 00000000 00000000 00B0 00000000 00000003 00000014 000000B0 00C0 000000B0 00000104 009CF700 00000000 7 00D0 00000000 C9D4D3C5 C4D4C193 D7E6E740 IMLEDMAlPWX 00E0 40404040 C980E2C2 F2C9D4E2 C5C30000 I SB2IMSEC . . . . . . . . . . Default 5000 or RECORDS= threshold reached PWXEDM172198I Reader UTILITY ERDS01 reader terminates due to an operator stop or reader termination PWXEDM175039I Reader UTILITY for member ERDS01 ended due to operator STOP or PAC termination Totals by Source.............. IMLEDMAls2aaseg100000 Isrt= 2 Repl= 0 Dlet= 2 Segm= 0 Evnt= 0 Unk= 0 IMLEDMAls2baseg100000 Isrt= 2 Repl= 0 Dlet= 2 Segm= 0 Evnt= 0 Unk= 0 IMLEDMAls2caseg100000 Isrt= 4 Repl= 0 Dlet= 4 Segm= 0 Evnt= 0 Unk= 0 Open Uows..................... Edp-UOW=SB2L 000000005A3000000000 LogRBA=000000005A300000 ECCR-UOW=SB2IMSEC E2C2F2C9D4E2C5C3 000000000000002D EDMMSG log end