Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange CDC Introduction
  3. Part 2: PowerExchange CDC Components
  4. Part 3: PowerExchange CDC Data Sources
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: DTL__CAPXTIMESTAMP Time Stamps

CDC Guide for Linux, UNIX, and Windows

CDC Guide for Linux, UNIX, and Windows

Configuring PowerExchange CDC with the PowerExchange Logger

Configuring PowerExchange CDC with the PowerExchange Logger

If you plan to run extractions in batch or continuous extraction mode and use the PowerExchange Logger for Linux, UNIX, and Windows, complete this procedure to configure PowerExchange CDC.
  1. When you configure the dbmover configuration file, define the following statements:
    • CAPT_PATH
    • CAPT_XTRA
    • MSQL CAPI_CONNECTION
    • CAPX CAPI_CONNECTION (for continuous extraction mode only)
  2. Configure the pwxccl configuration file for the PowerExchange Logger.
  3. In the PowerExchange Navigator, create a capture registration for each SQL Server source table.
    You must set the
    Condense
    option to
    Part
    . If capture registrations already exist for these tables, you can edit the
    Condense
    option without affecting the registration version.
    The PowerExchange Navigator generates a corresponding extraction map.
  4. Start the PowerExchange Logger.
  5. Activate the capture registrations.
    Usually, you do this task after materializing the targets.
Next Step:
Configure and start extractions. You can use either batch extraction mode or continuous extraction mode.