Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange CDC Introduction
  3. Part 2: PowerExchange CDC Components
  4. Part 3: PowerExchange CDC Data Sources
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: DTL__CAPXTIMESTAMP Time Stamps

CDC Guide for Linux, UNIX, and Windows

CDC Guide for Linux, UNIX, and Windows

Application Names

Application Names

PWXPC, in conjunction with the PowerCenter Integration Service, uses the application name you specify as part of the key when it stores and retrieves the restart information for a CDC session.
When you configure the PWX CDC application connection for a CDC session, enter a unique value for the
Application Name
 attribute. PWXPC appends the repository task instance ID for the CDC session to this value to create the APPL_ID value in the recovery state table and the
appl_id
portion of the recovery state file name.
Because the value of the APPL_ID column and the state recovery file contains the task instance ID for the CDC session, changes to the session can affect restart processing. If you add or remove sources or targets for a CDC session, you must use the restart token file to provide restart tokens and then cold start the session.