Hi, I'm Ask INFA!
What would you like to know?
ASK INFAPreview
Please to access Ask INFA.

Table of Contents

Search

  1. Preface
  2. Getting started
  3. Before you begin
  4. Installing Secure Agents
  5. Create a CDI-PC domain
  6. Join a CDI-PC domain
  7. Run the silent installer
  8. Resuming an installation
  9. Before you migrate the Informatica domain
  10. Migrate the domain
  11. Migrate the domain with changes to node configuration
  12. Migrate the domain in silent mode
  13. After you migrate the domain
  14. Install the CDI-PC Client
  15. EBF installation
  16. Uninstall Cloud Data Integration for PowerCenter (CDI-PC)
  17. Uninstalling the CDI-PC Client
  18. Uninstalling the Secure Agent
  19. Appendix A: CDI-PC components

Installation Guide

Installation Guide

Configure the ports

Configure the ports

You can update the port numbers for the Service Manager and Informatica Administrator.
  1. On the
    Port Configuration
    page, enter the port numbers to use for the domain service manager and service processes that will run on the node.
    Verify that the port numbers you enter are not used by other applications.
    The following table describes the ports that you can set:
    Port
    Description
    Service Manager port
    Port number used by the Service Manager on the node. The Service Manager listens for incoming connection requests on this port. Client applications use this port to communicate with the services in the domain. The Informatica command line programs use this port to communicate to the domain. This is also the port for the SQL data service JDBC/ODBC driver. Default is 6006.
    Service Manager shutdown port
    Port number that controls server shutdown for the domain Service Manager. The Service Manager listens for shutdown commands on this port. Default is 6007.
    Informatica Administrator port
    Port number used by Informatica Administrator. Default is 6008.
    Informatica Administrator HTTPS port
    No default port. Enter the required port number when you create the service. Setting this port to 0 disables an HTTPS connection to the Administrator tool.
    Informatica Administrator shutdown port
    Port number that controls server shutdown for Informatica Administrator. Informatica Administrator listens for shutdown commands on this port. Default is 6009.
    Minimum port number
    Lowest port number in the range of dynamic port numbers that can be assigned to the application service processes that run on this node. Default is 6014.
    Maximum port number
    Highest port number in the range of dynamic port numbers that can be assigned to the application service processes that run on this node. Default is 6114.
  2. Click
    Next
    .
    The
    Windows Service Configuration
    page appears.

0 COMMENTS

We’d like to hear from you!