Configuring Clients for Remote Server Shutdown and Startup

Configuring Clients for Remote Server Shutdown and Startup

  1. On the
    Data Integration Hub
    server, open the following security configuration file:
    <
    DIH
    InstallationDir>\conf\security\dx-security-config.properties
  2. In the security configuration file, in the
    dx.security.dxcontrol.whitelist
    property, enter the IP addresses of the clients from which users can remotely shut down and start up the
    Data Integration Hub
    server, separated by a semi colon.
    For example:
    dx.security.dxcontrol.whitelist=192.168.1.1;192.168.1.2;192.168.1.3;fe80::3516:cd0c:6f8:df39%19;