CMN_ 1075

CMN_
1075

ERROR: Data overflow.
A numeric data overflow occurred. One of the rows exceeded the declared precision in the target column. The Integration Service writes that row to the session reject file, and sometimes to the session log, depending on the session tracing level. If you enabled row error logging, the Integration Service writes the row to the error log.
Check the session reject file or error log to find the row. If this is a recurring error, you may want to change the precision of the target transformation column.