An attempt was made to register a table using the DTLUCBRG utility, but no columns were retrieved for the table.
If TESTRUN=Y, DTLUCBRG does not register the specified table and continues processing with the next available table. Otherwise, processing ends.
DTLUCBRG runs using client code pages set for metadata. The utility uses IBM037 on i5/OS, IBM1047 on z/OS and UTF8 on Linux, UNIX or Windows. It might not be possible to run DTLUCBRG locally if it processes a table name that contains characters that have different values in the code page that the database uses.
Set the LOCATION parameter to a PowerExchange Listener that uses the required SQL code page. It is possible to run DTLUCBRG from a Linux, UNIX or Windows machine and create registrations and extraction data maps on z/OS or i5/OS.