PWX- 23515

PWX-
23515

Code page number
code_page_number
has not been defined.
No definition for the code page number exists in the control array. This error can occur for the following reasons:
  • A customized code page in the range 301 to 399 is used but has not been defined with an ICUCONVERTER ADD statement.
  • An ICUCONVERTER DELETE statement removed the specified code page number.
Processing ends.
Verify that the required ICUCONVERTER ADD statements are defined in the DBMOVER configuration file. If an NRDB data map exists, make sure that it has the correct code page at the map and field levels. If you need assistance, collect as much information as possible about the error and then contact Informatica Global Customer Support.