PWX- 14521

PWX-
14521

File lrecl
nnn
not compatible with requested max trace record size
nnn
.
The logical record length of the alternative log file that was used by a prior invocation of this process is not compatible with the RECLEN parameter specified on the TRACING statement in the DBMOVER configuration file.
Alternative logging ignores APPEND processing and uses the next log file to begin logging data.
The problem corrects as the alternative logging task cycles through the log files for the process.