PWX- 36977

PWX-
36977

Decryption key validation failed.
The log reader was unable to validate the decryption key. The decryption key is required to decrypt PowerExchange Logger for Linux, UNIX, and Windows log files that are encrypted. The PowerExchange Logger CDCT file might be corrupted, or an incorrect encryption password might have been entered in the RESTORE_CDCT command of the PWXUCDCT utility for a CDCT restore operation.
Processing ends.
Cold start the PowerExchange Logger. If the problem occurs again, contact Informatica Global Customer Support.