PWX- 31506

PWX-
31506

Offloading must be specified in PowerCenter connection dialog
Offloading must be specified in the PowerCenter connection dialog box.
Processing continues.
Perform the following steps:
  1. Remove any OFFLOAD settings from the configuration file for the PowerExchange Listener.
  2. Remove any offloading setting from the PowerExchange data map.
  3. Specify the offloading setting in the PowerCenter Connect to Repository dialog box.