Table of Contents

Search

  1. Preface
  2. PWX-10000 to PWX-10999
  3. PWX-11000 to PWX-15999
  4. PWX-16000 to PWX-23999
  5. PWX-25000 to PWX-35999
  6. PWX-36000 to PWX-36999
  7. PWX-37100 to PWX-37999
  8. PWX-38500 to PWX-38999
  9. DTL_BMG003 to DTL_RPS105I
  10. infacmd pwx Error Messages
  11. PWXPC Error Messages
  12. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 2

Message Reference Volume 2

PWX- 33289

PWX-
33289

Condense: Condense completed. Total Records=
count
, Inserts=
count
, Updates=
count
, Deletes=
count
, UOWs=
count
This message reports counts of processed change records and UOWs for the last PowerExchange Logger for Linux, UNIX, and Windows run or logging cycle. The message includes the following counts:
  • The total number of records that were processed since logging activity began.
  • The number of Delete, Insert, and Update records that were processed. Before-image (type T) records are not included in these counts.
  • The number of units of work (UOWs) that were processed.
PowerExchange Logger processing ends or continues, depending on the execution mode:
  • If the PowerExchange Logger is running in batch mode, it shuts down.
  • If the PowerExchange Logger is running in continuous mode, the PowerExchange Logger task sleeps for the number of minutes that is specified in the NO_DATA_WAIT parameter and then starts another logging cycle.
No response is required.

0 COMMENTS

We’d like to hear from you!