DL1_INITIAL_CHKP Statement

DL1_INITIAL_CHKP Statement

The DL1_INITIAL_CHKP statement controls whether PowerExchange sets an initial checkpoint for IMS netport jobs. If you enable PowerExchange to set an initial checkpoint and a netport job encounters a problem, you can use the initial checkpoint to perform a ROLLBACK to the beginning of a job.
z/OS
Data Source:
IMS
No
DL1_INITIAL_CHKP ={
N
|Y}
  • N
    .
    PowerExchange does not set an initial checkpoint for IMS netport jobs.
  • Y.
    PowerExchange sets an initial checkpoint for each IMS netport job immediately after the netport job starts.
Default is N.