Stopping a Batch VSAM ECCR Job

Stopping a Batch VSAM ECCR Job

When you stop a batch VSAM ECCR job, PowerExchange no longer captures change data for any VSAM data sets in that batch job. The batch VSAM ECCR running in the batch job disconnects from the PowerExchange Logger and displays a set of messages, including the number and type of changes captured since the last time the VSAM data sets were opened. For example:
PWXEDM172818I Joined XCF group 'AUSL' as member 'AUSVSUPD' PWXEDM172841I EDM ECCR AUSVSUPD connected to EDM Logger AUSL, Log RBA=X'0000560078040000' PWXEDM172808I Change Capture active for Tag VSAMAUSQA.VSAM.VSMDEMO1 VSAM file AUSQA.VSAM.VSMDEMO1 PWXEDM172809I Change Capture counts for AUSQA.VSAM.VSMDEMO1: Insert=0, Update=5, Delete=0 PWXEDM172841I EDM ECCR AUSVSUPD disconnected from EDM Logger AUSL, Log RBA=X'0000560084DD0000' PWXEDM172818I Left XCF group 'AUSL' as member 'AUSVSUPD' PWXEDM172829I EDM ECCR sent 5 records to Logger AUSL (5 change records)

0 COMMENTS