Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange Change Data Capture Introduction
  3. Part 2: CDC Components Configuration and Management
  4. Part 3: CDC Sources Configuration and Management
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: CDC for z/OS Troubleshooting
  8. Appendix B: DTL__CAPXTIMESTAMP Time Stamps

NO_DATA_WAIT Parameter

NO_DATA_WAIT Parameter

The number of seconds that the IMS log-based ECCR waits after an end-of-log condition before it starts the next log read operation.
During the next read operation, if the ECCR receives another end-of-log condition without having processed new changes, the NO_DATA_WAIT_2 parameter takes effect.
NO_DATA_WAIT2
NO_DATA_WAIT={
60
|
seconds
}
For the
seconds
variable, enter a number from 1 to 99999999.
Default is 60.