The Process
processName
with the thread ID
threadID
determined that the Connector
connectorName
references the Queue Adapter Extractor name
extractName
, but that name is not in the configuration parameter
configKey
.
The Queue Adapter Connector is configured but references an Extractor name that is not specified for the Connector in the configuration. This error message includes the Connector name, the Extractor name that cannot be found, and the Connector configuration parameter that specifies the Extractor name.
Correct the specified Extractor name In the Connector definition in the configuration, or add the name of an existing Extractor process in the specified configuration parameter.