Number(P,S) Data Type

Number(P,S) Data Type

The Developer tool supports Oracle Number(P,S) values with negative scale.
However, it does not support Number(P,S) values with scale greater than precision 38 or a negative precision.
If you import a table with an Oracle Number with a negative scale, the Developer tool displays it as a Decimal data type. However, the Data Integration Service converts it to a double.