Table of Contents

Search

  1. Preface
  2. Command Line Programs and Utilities
  3. Installing and Configuring Command Line Utilities
  4. Using the Command Line Programs
  5. Environment Variables for Command Line Programs
  6. Using infacmd
  7. infacmd as Command Reference
  8. infacmd aud Command Reference
  9. infacmd autotune Command Reference
  10. Infacmd bg Command Reference
  11. infacmd ccps Command Reference
  12. infacmd cluster Command Reference
  13. infacmd cms Command Reference
  14. infacmd dis Command Reference
  15. infacmd dp Command Reference
  16. infacmd idp Command Reference
  17. infacmd edp Command Reference
  18. Infacmd es Command Reference
  19. infacmd ihs Command Reference
  20. infacmd ipc Command Reference
  21. infacmd isp Command Reference
  22. infacmd ldm Command Reference
  23. infacmd mas Command Reference
  24. infacmd mi Command Reference
  25. infacmd mrs Command Reference
  26. infacmd ms Command Reference
  27. infacmd oie Command Reference
  28. infacmd ps Command Reference
  29. infacmd pwx Command Reference
  30. infacmd roh Command Reference
  31. infacmd rms Command Reference
  32. infacmd rtm Command Reference
  33. infacmd sch Command Reference
  34. infacmd search Command Reference
  35. infacmd sql Command Reference
  36. infacmd tdm Command Reference
  37. infacmd tools Command Reference
  38. infacmd wfs Command Reference
  39. infacmd ws Command Reference
  40. infacmd xrf Command Reference
  41. infacmd Control Files
  42. infasetup Command Reference
  43. pmcmd Command Reference
  44. pmrep Command Reference
  45. Working with pmrep Files

Command Reference

Command Reference

Virtual Table Options

Virtual Table Options

Use the virtual table options to configure caching for a virtual table. Use the virtual table options with the infacmd sql UpdateTableOptions command.
Enter virtual table options in the following format:
... -o option_type.option_name=value ...
To enter multiple options, separate them with a space. To enter a value that contains a space or other non-alphanumeric character, enclose the value in quotation marks.
The following table describes virtual table options:
Option
Description
VirtualTableOptions.CachingEnabled
Cache the virtual table in the data object cache database. True or false. Default is true.
VirtualTableOptions.CacheRefreshPeriod
Number of minutes between cache refreshes. Default is zero.
VirtualTableOptions.CacheTableName
The name of the user-managed table from which the Data Integration Service accesses the virtual table cache. A user-managed cache table is a table in the data object cache database that you create, populate, and manually refresh when needed.
If you specify a cache table name, the Data Object Cache Manager does not manage the cache for the object and ignores the cache refresh period. If you do not specify a cache table name, the Data Object Cache Manager manages the cache for the object.