Configuring ODBC Connectivity

Configuring ODBC Connectivity

You can configure ODBC connectivity to a Teradata database.
The following steps provide a guideline for configuring ODBC connectivity. For specific instructions, see the database documentation.
  1. To configure connectivity for the integration service process, log in to the machine as a user who can start a service process.
  2. Set the TERADATA_HOME, ODBCHOME, and PATH environment variables.
    TERADATA_HOME
    . Set the variable to the Teradata driver installation directory. The defaults are as follows:
    Using a Bourne shell:
    $ TERADATA_HOME=/opt/teradata/client/<version>; export TERADATA_HOME
    Using a C shell:
    $ setenv TERADATA_HOME /opt/teradata/client/<version>
    ODBCHOME
    . Set the variable to the ODBC installation directory. For example:
    Using a Bourne shell:
    $ ODBCHOME=$INFA_HOME/ODBC<version>; export ODBCHOME
    Using a C shell:
    $ setenv ODBCHOME $INFA_HOME/ODBC<version>
    PATH
    . To run the
    ddtestlib
    utility, to verify that the DataDirect ODBC driver manager can load the driver files, set the variable as follows:
    Using a Bourne shell:
    PATH="${PATH}:$ODBCHOME/bin:$TERADATA_HOME/bin"
    Using a C shell:
    $ setenv PATH ${PATH}:$ODBCHOME/bin:$TERADATA_HOME/bin
  3. Set the shared library environment variable.
    The Teradata software contains multiple shared library components that the integration service process loads dynamically. Set the shared library environment variable so that the services can find the shared libraries at run time.
    The shared library path must also include installation directory of the Informatica service
    (server_dir)
    .
    Set the shared library environment variable based on the operating system.
    The following table describes the shared library variables for each operating system:
    Operating System
    Variable
    Linux
    LD_LIBRARY_PATH
    AIX
    LIBPATH
    For example, use the following syntax for Linux:
    • Using a Bourne shell:
      $ LD_LIBRARY_PATH="${LD_LIBRARY_PATH}:$HOME/
      server_dir
      :$ODBCHOME/lib: $TERADATA_HOME/lib64:$TERADATA_HOME/odbc_64/lib"; export LD_LIBRARY_PATH
    • Using a C shell:
      $ setenv LD_LIBRARY_PATH "${LD_LIBRARY_PATH}:$HOME/
      server_dir
      :$ODBCHOME/lib:$TERADATA_HOME/lib64: $TERADATA_HOME/odbc_64/lib"
    For AIX
    • Using a Bourne shell:
      $ LIBPATH=${LIBPATH}:$HOME/
      server_dir
      :$ODBCHOME/lib:$TERADATA_HOME/lib64:$TERADATA_HOME/odbc_64/lib; export LIBPATH
    • Using a C shell:
      $ setenv LIBPATH ${LIBPATH}:$HOME/
      server_dir
      :$ODBCHOME/lib:$TERADATA_HOME/lib64: $TERADATA_HOME/odbc_64/lib
  4. Edit the existing odbc.ini file or copy the odbc.ini file to the home directory and edit it.
    This file exists in $ODBCHOME directory.
    $ cp $ODBCHOME/odbc.ini $HOME/.odbc.ini
    Add an entry for the Teradata data source under the section [ODBC Data Sources] and configure the data source.
    For example, for Teradata Parallel Transporter utilities:
    TERADATA_DSN=DataDirect 7.1 Teradata [TERADATA_DSN] Driver=/opt/teradata/client/<version>/lib64/tdataodbc_sb64.so Description=NCR 3600 running Teradata V1R5.2 DBCName=<hostname> LastUser= Username= Password= Database= DefaultDatabase= UseNativeLOBSupport=Yes CharacterSet=UTF8 SessionMode=ANSI
  5. Set the DateTimeFormat to AAA in the Teradata data ODBC configuration.
  6. Optionally, set the SessionMode to ANSI. When you use ANSI session mode, Teradata does not roll back the transaction when it encounters a row error.
    If you choose Teradata session mode, Teradata rolls back the transaction when it encounters a row error. In Teradata mode, the integration service process cannot detect the rollback, and does not report this in the session log.
  7. To configure connection to a single Teradata database, enter the DefaultDatabase name. To create a single connection to the default database, enter the user name and password. To connect to multiple databases, using the same ODBC DSN, leave the DefaultDatabase field empty.
    For more information about Teradata connectivity, see the Teradata ODBC driver documentation.
  8. Verify that the last entry in the odbc.ini is InstallDir and set it to the odbc installation directory.
    For example:
    InstallDir=<Informatica installation directory>/ODBC<version>
  9. Edit the .cshrc or .profile to include the complete set of shell commands.
  10. Save the file and either log out and log in again, or run the source command.
    Using a Bourne shell:
    $ source .profile
    Using a C shell:
    $ source .cshrc
  11. For each data source you use, make a note of the file name under the Driver=<parameter> in the data source entry in odbc.ini. Use the
    ddtestlib
    utility to verify that the DataDirect ODBC driver manager can load the driver file.
    For example, if you have the driver entry:
    Driver=/u01/app/teradata/td-tuf611/odbc/drivers/tdata.so
    run the following command:
    ddtestlib /u01/app/teradata/td-tuf611/odbc/drivers/tdata.so
  12. Test the connection using BTEQ or another Teradata client tool.