PWX- 21082

PWX-
21082

Function
function
does not support direction argument 2 value of
value
.
The specified function does not support a particular attribute value. For example, function CALLPROG does not support more than 20 arguments. Function CALLPROG only supports particular linkage types depending on which operating system it is being run on. Associated messages include 21080 that shows available values for the attribute, and PWX-02603 that identifies the problem E Field.
The task ends.
Locate the problem E Field by using message PWX-02603. Correct the E Field using the PowerExchange Navigator, save the data map, send it to the remote node and rerun the task.