PWX- 32601

PWX-
32601

Command Handler failed to create a connection to
remote_service
.
The pwxcmd command handler failed to establish communication with the specified command-handing service for a PowerExchange Listener, PowerExchange Condense, or PowerExchange Logger for Linux, UNIX, and Windows process.
The pwxcmd command processing ends.
Verify the following:
  • The CMDNODE statement in the dbmover.cfg on the machine where you issued the command specifies the correct node name and port for the specified PowerExchange process.
  • The PowerExchange process that is the target of the pwxcmd command is operational.
  • When the PowerExchange process that is the target of the pwxcmd command was initialized, the command handler service started.
    If you cannot determine the cause of the failure, contact Informatica Global Customer Support.