PowerExchange for CDC and Mainframe
- PowerExchange for CDC and Mainframe 10.4.0
- All Products
Statement
| Description
| Reference
|
---|---|---|
LISTENER
| Required. Defines the
TCP/IP port on which a named PowerExchange Listener process listens for work requests.
| |
SECURITY
| Optional. Controls whether PowerExchange authenticates user access to PowerExchange and authorizes users to issue specific pwxcmd commands.
| |
SVCNODE
| Required. Specifies the TCP/IP port on which a PowerExchange Listener process listens for commands.
|
Statement
| Description
| Reference
|
---|---|---|
SVCNODE
| Required. Specifies the ECCR name and TCP/IP port on which the ECCR listens for commands.
|
Statement
| Configuration File
| Description
| Reference
|
---|---|---|---|
CONDENSENAME
| pwxccl.cfg file
| Required. Defines a name for the
command-handling service for a PowerExchange Logger process that is the target of pwxcmd commands.
| CDC guide for the operating system
|
SECURITY
| DBMOVER configuration file
| Optional. Controls whether PowerExchange authenticates user access to PowerExchange and authorizes users to issue specific pwxcmd commands.
| |
SVCNODE
| DBMOVER configuration file
| Required. Specifies the TCP/IP port on which a PowerExchange Logger for Linux, UNIX, and Windows process listens for commands.
|
Statement
| Configuration File
| Description
| Reference
|
---|---|---|---|
CMDNODE
| dbmover.cfg file