Table of Contents

Search

  1. Preface
  2. Introduction to PowerExchange Utilities
  3. createdatamaps - Data Map Creation Utility
  4. DTLCCADW - Adabas PCAT Utility
  5. DTLCUIML - IMS Log Marker Utility
  6. DTLINFO - Release Information Utility
  7. DTLINFOX - Enhanced Release Information Utility
  8. DTLREXE - Remote Execution Utility
  9. DTLUAPPL - Restart Token Utility
  10. DTLUCBRG - Batch Registration Utility
  11. DTLUCDEP - CDEP Maintenance Utility
  12. DTLUCSR2 - IDMS SR2 and SR3 Records Utility
  13. DTLUCUDB - DB2 for Linux, UNIX, and Windows CDC Utility
  14. DTLULCAT and DTLULOGC - IDMS Log Catalog Utilities
  15. DTLURDMO - Data Map Utility
  16. DTLUTSK - Task Control Utility
  17. EDMLUCTR - Log Scan and Print Utility
  18. EDMUOPTS - Service Aid Utility
  19. EDMXLUTL - Event Marker Utility
  20. HOSTENT - TCP/IP Address Reporter Utility
  21. PWXCATMY - MySQL Catalog Utility
  22. PWXUCCLPRT - Print Log Summary Utility
  23. PWXUCDCT - Logger for Linux, UNIX, and Windows Utility
  24. PWXUCREG - Capture Registration Utility
  25. PWXUMAP - Map List Utility
  26. PWXUCRGP - Capture Registrations Print Utility
  27. PWXUDMX - Data Maps Update Time ECSA Memory Utility
  28. PWXUGSK - SSL Reporting Utility
  29. PWXUSSL - PowerExchange SSL Reporting Utility
  30. WRKJRNLCKE- Journal Lock Table Utility for IBM i

PWXUCREG Utility Overview

PWXUCREG Utility Overview

Use the PWXUCREG utility to delete capture registrations, report capture registrations, or temporarily suspend capture registrations for certain z/OS database types from change capture.
Use the utility to perform the following tasks:
  • Delete inactive registrations that have the status of History, Inactive, or Non-Live.
  • Display the current status of each capture registration, according to the filters you supply, to verify a status change
    The PWXUCREG utility does not provide detailed reports. If you need more detail, Informatica recommends that you use the PWXUCRGP utility to create reports on registrations.
  • Temporarily suspend ECCR change data capture from Adabas, Datacom, IDMS, or IMS log-based sources. Later, you can use the utility to reactivate the suspended registrations to resume change data capture.
When you delete or suspend capture registrations, the registration information in the CCT file is updated.
To display help information about PWXUCREG commands and parameters, enter a question mark (?) at the command line. For example:
  • PWXUCREG ?
  • PWXUCREG ? ALL
  • PWXUCREG ? DISPLAY_INACTIVE_REGISTRATIONS