PWX- 15808

PWX-
15808

Unable to process journal
journal_library
journal_name
. Journal has
current_file_count
files journaled to it, which exceeds the PowerExchange maximum of
maximum_files_allowed
files.
PowerExchange Db2 for i CDC cannot process the specified IBM i journal because too many physical files are currently being journaled to it.
The PowerExchange CDC task that reads the IBM i journals fails.
Reduce the number of files that are journaled to the specified journal to less than the maximum number of files allowed. Then, start the task again.