Message Reference Volume 2

PWX- 31201

PWX-
31201

Threading not supported (reason:
reason_code
) - reverting to single threaded mode
The PowerCenter session cannot use multithreaded processing.
The specified reason code is one of the following values:
  • 0. Unknown.
  • 1. Parameters not supported.
  • 2. Non-ordered processing not supported.
  • 3. Only Group Source processing is supported.
  • 4. Offload processing is required for threading.
  • 5. Caller must manage restart tokens.
  • 6. Only local mode processing supported.
  • 7. Access Method not supported.
  • 8. DB Request type not supported.
  • 9. File format not supported.
  • 10. Late initial binds (post-first read) not supported.
The session runs in single-threaded mode.
To suppress this warning, change the value of the Worker Threads attribute to 0 on the PWXPC application connection.