Table of Contents

Search

  1. Preface
  2. PWX-10000 to PWX-10999
  3. PWX-11000 to PWX-15999
  4. PWX-16000 to PWX-23999
  5. PWX-25000 to PWX-35999
  6. PWX-36000 to PWX-36999
  7. PWX-37100 to PWX-37999
  8. PWX-38500 to PWX-38999
  9. DTL_BMG003 to DTL_RPS105I
  10. infacmd pwx Error Messages
  11. PWXPC Error Messages
  12. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 2

Message Reference Volume 2

PWX-37130

PWX-
37130

PWXCCL pid =
process_id
Writer status =
status
This monitoring message reports the PowerExchange Logger for Linux, UNIX, and Windows process ID (PID) and the status of the PowerExchange Logger Writer subtask. The
status
variable can be one of the following values:
  • Reading or waiting for source data
  • Sleeping
  • Writing to file
  • Not Started yet
  • Initializing
  • Initializing CAPI
  • Starting to process
  • Starting a checkpoint
  • Writing a checkpoint file
  • Shutting down
  • Terminated
This message is part of the report that is generated in response to a PowerExchange Logger DL (or DS) command or pwxcmd displaystats -tp logger command. Also, if you specify the STATS=(MONITOR) parameter, either with or without the
interval
subparameter, in the PowerExchange Logger configuration file, pwxccl.cfg, this message is issued when the PowerExchange Logger stops in response to a SHUTCOND or SHUTDOWN command or at the end of a batch run.
No response is required.