Table of Contents

Search

  1. Preface
  2. PWX-10000 to PWX-10999
  3. PWX-11000 to PWX-15999
  4. PWX-16000 to PWX-23999
  5. PWX-25000 to PWX-35999
  6. PWX-36000 to PWX-36999
  7. PWX-37100 to PWX-37999
  8. PWX-38500 to PWX-38999
  9. DTL_BMG003 to DTL_RPS105I
  10. infacmd pwx Error Messages
  11. PWXPC Error Messages
  12. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 2

Message Reference Volume 2

PWXPC_ 12129

PWXPC_
12129

[
process_id
] Restart entry for [
table_name
] in the GMD restart information matches no source for this session. When adding or removing sources perform recovery to retrieve existing restart information followed by cold start.
Table
table_name
is recorded in the GMD state restart information for this session. However, this table did not match any source in this session.
Processing terminates.
When adding or removing sources in CDC session, you must do the following:
  1. Run recovery on the original session to populate the restart token file.
  2. Alter the session to add or remove the source or target table.
  3. If adding a source table, update the restart token file to provide restart tokens for the new source.
  4. Cold start the session.

0 COMMENTS