Troubleshooting for Code Page Relaxation

Troubleshooting for Code Page Relaxation

The PowerCenter Integration Service failed a session and wrote the following message to the session log:
TM_6188 The specified sort order is incompatible with the PowerCenter Integration Service code page.
If you want to validate code pages, select a sort order compatible with the PowerCenter Integration Service code page. If you want to relax code page validation, configure the PowerCenter Integration Service to relax code page validation in Unicode data movement mode.
I tried to view the session or workflow log, but it contains garbage characters.
The PowerCenter Integration Service is not configured to write session or workflow logs using the UTF-8 character set.
Enable the LogsInUTF8 option in the PowerCenter Integration Service properties.