Table of Contents

Search

  1. Preface
  2. Data Replication Overview
  3. Understanding Data Replication
  4. Sources - Preparation and Replication Considerations
  5. Targets - Preparation and Replication Considerations
  6. Starting the Server Manager
  7. Getting Started with the Data Replication Console
  8. Defining and Managing Server Manager Main Servers and Subservers
  9. Creating and Managing User Accounts
  10. Creating and Managing Connections
  11. Creating Replication Configurations
  12. Materializing Targets with InitialSync
  13. Scheduling and Running Replication Tasks
  14. Implementing Advanced Replication Topologies
  15. Monitoring Data Replication
  16. Managing Replication Configurations
  17. Handling Replication Environment Changes and Failures
  18. Troubleshooting
  19. Data Replication Files and Subdirectories
  20. Data Replication Runtime Parameters
  21. Command Line Parameters for Data Replication Components
  22. Updating Configurations in the Replication Configuration CLI
  23. DDL Statements for Manually Creating Recovery Tables
  24. Sample Scripts for Enabling or Disabling SQL Server Change Data Capture
  25. Glossary

Setting Advanced Parameters for the InitialSync, Extractor, and Applier Tasks

Setting Advanced Parameters for the InitialSync, Extractor, and Applier Tasks

On the
Runtime Settings
tab >
Advanced Settings
view, you can specify runtime parameters for the InitialSync, Extractor, and Applier programs.
Data Replication supplies default values for most of the parameters listed in the Console and in the AdvancedParameters.xml file in the
DataReplication_installation
/uiconf directory. If you edit the default values or add values for the few parameters that do not have defaults, the updated parameter values are included in the configuration. Also, you might need to add user-defined parameters at the direction of Informatica Global Customer Support.
For descriptions of the parameters that Data Replication supplies, see Data Replication Runtime Parameters.
  1. Click the
    Runtime Settings
    tab >
    Advanced Settings
    view.
    This view lists the runtime parameters that are applicable to the source and target that are defined for the replication job, including the default parameter values. The parameters are grouped by component or parameter type and listed under each group in alphabetical order.
    The following image shows the
    Advanced Settings
    view:
    Advanced Settings view on the Runtime Settings tab
  2. To edit a listed parameter value, perform the following substeps:
    1. Select the parameter and click
      Edit
      .
    2. In the
      Input
      dialog box, enter a new value and click
      OK
      .
      Data Replication validates the value against the AdvancedParameters.xml file. Data Replication checks that the value is within the minimum and maximum range of values, if applicable, and is consistent with the data type.
  3. To reset a listed parameter to its default value, select the parameter and click
    Reset
    .
    The
    Reset
    button does not affect any user-defined parameters.
  4. If you need to add a user-defined parameter at the direction of Informatica Global Customer Support, perform the following substeps:
    1. Click
      New
      .
    2. Enter the parameter name that Support supplies and click
      OK
      .
    3. Enter the parameter value and click
      OK
      .
      The new parameter appears under the
      User Defined
      section.
  5. To delete a user-defined parameter, select the parameter and click
    Delete
    .
    You can delete only user-defined parameters.

0 COMMENTS

We’d like to hear from you!