Table of Contents

Search

  1. Preface
  2. Command Line Programs and Utilities
  3. Installing and Configuring Command Line Utilities
  4. Using the Command Line Programs
  5. Environment Variables for Command Line Programs
  6. Using infacmd
  7. infacmd as Command Reference
  8. infacmd aud Command Reference
  9. infacmd autotune Command Reference
  10. Infacmd bg Command Reference
  11. infacmd ccps Command Reference
  12. infacmd cluster Command Reference
  13. infacmd cms Command Reference
  14. infacmd dis Command Reference
  15. Infacmd dis Queries
  16. infacmd dp Command Reference
  17. infacmd idp Command Reference
  18. infacmd edp Command Reference
  19. Infacmd es Command Reference
  20. infacmd ics Command Reference
  21. infacmd ipc Command Reference
  22. infacmd isp Command Reference
  23. infacmd ldm Command Reference
  24. infacmd mas Command Reference
  25. infacmd mi Command Reference
  26. infacmd mrs Command Reference
  27. infacmd ms Command Reference
  28. infacmd oie Command Reference
  29. infacmd ps Command Reference
  30. infacmd pwx Command Reference
  31. infacmd roh Command Reference
  32. infacmd rms Command Reference
  33. infacmd rtm Command Reference
  34. infacmd sch Command Reference
  35. infacmd search Command Reference
  36. infacmd sql Command Reference
  37. infacmd tdm Command Reference
  38. infacmd tools Command Reference
  39. infacmd wfs Command Reference
  40. infacmd ws Command Reference
  41. infacmd xrf Command Reference
  42. infacmd Control Files
  43. infasetup Command Reference
  44. pmcmd Command Reference
  45. pmrep Command Reference
  46. Working with filemanager
  47. Working with pmrep Files

updateDomainName

updateDomainName

Changes the domain name in the domain configuration database.
Before you update the domain name, you must back up the domain, the site specific key, and keytab files. If the PowerCenter repository contains a global repository, you must unregister all local repositories from the global repository.
To update the domain name, run the infasetup updateDomainName command from any gateway node.
After you update the domain, perform the following steps:
  1. Run the updateGatewayNode and updateWorkerNode commands with the updated domain name for all the gateway and worker nodes.
  2. You can register the local repository with a connected global repository with the updated domain name with the pmrep Register command.
  3. You can create SPN and keytab files with the updated domain name for Kerberos authentication. Copy the keytab files in the keys directory. You can continue to use the older site key file. If you need to regenerate the site key when it is missing or corrupted, you must provide the older domain name.
  4. You must configure the Informatica clients to use the updated domain name.
The updateDomainName command uses the following syntax:
updateDomainName -dn <domain_name>
The following table describes the
infasetup
updateDomainName option and argument:
Option
Argument
Description
-DomainName
-dn
domain_name
Required. Changes the domain name. Domain names must be between 1 and 79 characters and cannot contain spaces or the following characters: / * ? < > " |