Table of Contents

Search

  1. Preface
  2. Product Overview
  3. Security
  4. Applications
  5. Partner and Account Information
  6. Events
  7. Event Archiving
  8. User Policies
  9. Schedules
  10. B2B Data Exchange Administrative Tasks
  11. On-boarding Checklist Template
  12. System Properties
  13. Repository Management
  14. Document Management
  15. B2B Data Exchange Utilities
  16. Dashboard and Reports Management

Administrator Guide

Administrator Guide

PowerCenter System Properties

PowerCenter System Properties

PowerCenter system properties determine PowerCenter domain and connection management.
The following table describes PowerCenter system properties:
System Property
Description
pwc.domain.gateway
Name of the Informatica security domain gateway. The value of this property appears in the following format:
host_1:port_1(;host_2:port_2)
pwc.domain.name
Name of the domain where PowerCenter is installed.
pwc.integration.service.name
Name of the PowerCenter Integration Service to run batch workflows.
pwc.repository.jdbc.url
JDBC connection URL for the PowerCenter repository database.
Applicable for PowerCenter repositories that are hosted on Oracle or Microsoft SQL Server databases.
pwc.repository.jdbc.name
Database name of the PowerCenter repository database.
Applicable for PowerCenter repositories that are hosted on Oracle or Microsoft SQL Server databases.
pwc.repository.jdbc.password
Password for the PowerCenter repository database.
Applicable for PowerCenter repositories that are hosted on Oracle or Microsoft SQL Server databases.
pwc.repository.password
Password for the PowerCenter Repository Service.
You must restart the
B2B Data Exchange
Operation Console after you change the password for the PowerCenter Repository Service.
pwc.repository.service.name
Name of the PowerCenter Repository Service.
pwc.repository.user.name
Name of the PowerCenter Repository Service user.
pwc.retry.interval.sec
Time interval in seconds that the
B2B Data Exchange
server waits to retry running a workflow in an error state.
pwc.retry.max.count
Maximum number of times that the
B2B Data Exchange
server retries running a workflow if a failure occurs.
pwc.user.name.space
Name of the security domain that stores the PowerCenter repository user. If you use Informatica domain authentication, change the default to grant access to the PowerCenter repository.
Default value is Native.
pwc.webservices.url
URL or Web address of the PowerCenter Web Services Hub. For example:
http://localhost:7333/wsh/services/BatchServices/DataIntegration