HIPAA Accelerator Guide

HIPAA Accelerator Guide

Interchange (ISA) Processing

Interchange (ISA) Processing

Valid messages are Serialized and sent to the partner and are attached to the DX event. If the message is valid, the DX event status is set to 'Complete' and next level processing begins.
When validation errors are found, a document with errors description is attached to the DX event and the Event status is set to 'Validation Error'.

Event statuses

DX Event Status
Description
Invalid File
File structure is not recognized as Informatica XML canonical format
Exception
The HIPAA document is not supported by the HIPAA accelerator or the corresponding Data Transformation HIPAA library service does not reside in the Data Transformation server Service DB
Validation Error
Document content does not conform to the HIPAA standard
Complete
ISA envelope valid and processing continues to next level

Event types

The event type format is '<Hipaa document identifier>(ISA)-->'. For example, the event type will be '
820 (ISA)-->
' for HIPAA Document 820.

Event attributes

none

Documents attached

Log Name
Description
Input message
The incoming message in Informatica canonical XML format (data from the backend system after transformation to the Informatica XML canonical format)
Output message
Serialized HIPAA file that is sent to the partner
Logging information
Error description and additional information in case of an error

0 COMMENTS