Configure transformation properties that the Integration Service uses to generate sequential values.
The following list describes the Sequence Generator transformation properties that you can configure:
Start Value
Start value of the generated sequence that you want the Integration Service to use if you use the Cycle option. If you select Cycle, the Integration Service cycles back to this value when it reaches the end value.
Default is 0.
Maximum value is 9,223,372,036,854,775,806.
Increment By
Difference between two consecutive values from the NEXTVAL port.
Default is 1.
Must be a positive integer.
Maximum value is 2,147,483,647.
End Value
Maximum value that the Integration Service generates. If the Integration Service reaches this value during the session and the sequence is not configured to cycle, the session fails.
Maximum value is 9,223,372,036,854,775,807.
If you connect the NEXTVAL port to a downstream integer port, set the end value to a value no larger than the integer maximum value. If the NEXTVAL exceeds the datatype maximum value for the downstream port, the session fails.
Current Value
Current value of the sequence. Enter the value you want the Integration Service to use as the first value in the sequence. To cycle through a series of values, the value must be greater than or equal to the start value and less than the end value.
If the Number of Cached Values is set to 0, the Integration Service updates the current value to reflect the last-generated value for the session plus one, and then uses the updated current value as the basis for the next time you run this session. However, if you use the Reset option, the Integration Service resets this value to its original value after each session.
If you edit this setting, you reset the sequence to the new setting. If you reset Current Value to 10, and the increment is 1, the next time you use the session, the Integration Service generates a first value of 10.
Maximum value is 9,223,372,036,854,775,806. The Integration Service sets the value to NULL if the current value exceeds the maximum value.
Cycle
If enabled, the Integration Service cycles through the sequence range and starts over with the start value.
If disabled, the Integration Service stops the sequence at the configured end value. The Integration Service fails the session with overflow errors if it reaches the end value and still has rows to process.
Number of Cached Values
Number of sequential values the Integration Service caches at a time. Use this option when multiple sessions use the same reusable Sequence Generator at the same time to ensure each session receives unique values. The Integration Service updates the repository as it caches each value. When set to 0, the Integration Service does not cache values.
Default value is 0.
Default value for a reusable Sequence Generator is 1,000.
Maximum value is 9,223,372,036,854,775,807.
This property is applicable only for the reusable Sequence Generator transformations.
Reset
If enabled, the Integration Service generates values based on the original current value for each session. If disabled, the Integration Service updates the current value to reflect the last-generated value for the session plus one, and then uses the updated current value as the basis for the next session run.
This property is applicable only for the non-reusable Sequence Generator transformations.
Tracing Level
Level of detail about the transformation that the Integration Service writes into the session log.