Oracle Capture: Invalid restart token passed to Oracle Capture:
Explanation
.
The restart information passed to Oracle Capture is invalid. The rest of the message describes the details of the problem.
Oracle Capture processing ends.
This is most likely an operational error. It either occurs when a new Oracle table is incorrectly defined to PowerExchange, when a request to capture uses restart information from a different Oracle instance than the one to which Oracle Capture is connecting, or when a non-Oracle data source is passed to Oracle Capture. It can also happen if the restart information was manually adjusted in an incorrect manner. Determine the source of the problem, fix the problem, and restart Oracle Capture.