PWX-37430

PWX-
37430

Error: A change has been detected to the binlog basename or location configuration during a server reconnection.
The PowerExchange Logger for Linux, UNIX, and Windows detected a change in the location or base name of the MySQL binary log when reconnecting to the MySQL server.
MySQL capture processing ends.
If only the location of the binary log changed and the existing binlog files were copied to the new location, you can warm start the PowerExchange Logger to resume capture processing without change data loss. If the base name of the binary log changed, you must cold start the PowerExchange Logger. In this case, some change data might be lost.