Table of Contents

Search

  1. Preface
  2. PWX-10000 to PWX-10999
  3. PWX-11000 to PWX-15999
  4. PWX-16000 to PWX-23999
  5. PWX-25000 to PWX-35999
  6. PWX-36000 to PWX-36999
  7. PWX-37100 to PWX-37999
  8. PWX-38500 to PWX-38999
  9. DTL_BMG003 to DTL_RPS105I
  10. infacmd pwx Error Messages
  11. PWXPC Error Messages
  12. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 2

Message Reference Volume 2

PWX-15760

PWX-
15760

Reconnecting to SQL Server: Attempt
attempt_count
of
maximum_attempts
. Pausing
number_of_seconds
second(s).
PowerExchange tried to reconnect to the Microsoft SQL Server database for CDC processing after the connection was dropped. This message reports the current count of attempts made and the maximum number of attempts allowed. The maximum number of attempts is set in the RECONNTRIES parameter in the MSQL CAPI_CONNECTION statement of the dbmover.cfg file. PowerExchange pauses the specified number of seconds before making another reconnection attempt based on the RECONNWAIT parameter value in the MSQL CAPI_CONNECTION statement.
No response is required.

0 COMMENTS