PWX- 10922

PWX-
10922

Oracle Capture: Data error in {“Before image"|"After image”}. Messages follow.
A data conversion error occurred while processing the current log record.
Oracle Capture processing ends.
Inspect the error messages both before and after this message to retrieve the details of the error. The details include the table and column in error, and the data that caused the conversion error. This is most likely caused when the Oracle definition of the table in question and the PowerExchange registration definition of the table do not match. Reregister your table to PowerExchange, using the correct definition for the table.