PWX- 32532

PWX-
32532

An incoming connection contained an invalid Service type. Connection to Service
service
refused.
A command-handling service for a PowerExchange Listener, PowerExchange Condense, or PowerExchange Logger for Linux, UNIX, and Windows process received a request from a client to open a channel. However, the client specified an incorrect service type.
The PowerExchange command-handling service rejects the channel request. Processing continues.
Review the CMDNODE statement in the DBMOVER configuration file. Verify that the service type matches the service type of the PowerExchange command-handling service that is listening on the remote machine. Valid service types are LISTENER and CONDENSE.