Example PowerCenter Client Resilience to Application Services

Example PowerCenter Client Resilience to Application Services

There is a network connection loss of 120 seconds between the PowerCenter Workflow Monitor and the PowerCenter Repository Service when a developer is monitoring a workflow. The PowerCenter client, Workflow Monitor has a 60 second resilience timeout and the PowerCenter Repository Service has a resilience timeout of 180 seconds.
The Developer does not notice the loss of connection and he is unaffected by the 120 seconds connection loss. However, the following messages appear in the
Notifications
tab on the PowerCenter Workflow Monitor:
Repository Service notifications are enabled. DATE TIME-[REP_55101] Connection to the Repository Service [Repository_Service_Name] is broken. DATE TIME-[REP_55114] Reconnecting to the Repository Service [Repository_Service_Name]. The resilience time is 180 seconds. DATE TIME-Reconnected to Repository Service [Repository_Service_Name] successfully.