Table of Contents

Search

  1. Preface
  2. Understanding Domains
  3. Managing Your Account
  4. Using Informatica Administrator
  5. Using the Domain View
  6. Domain Management
  7. Nodes
  8. High Availability
  9. Connections
  10. Connection Properties
  11. Schedules
  12. Domain Object Export and Import
  13. License Management
  14. Monitoring
  15. Log Management
  16. Domain Reports
  17. Node Diagnostics
  18. Understanding Globalization
  19. Appendix A: Code Pages
  20. Appendix B: Custom Roles
  21. Appendix C: Informatica Platform Connectivity
  22. Appendix D: Configure the Web Browser

Administrator Guide

Administrator Guide

Example Resilience Timeout Configuration

Example Resilience Timeout Configuration

Some resilience timeout values are default and others can be configured or overwritten.
You can use the resilience timeout and limit on resilience timeout configured for the domain for PowerCenter application services if you do not set it for the application service. Command line programs use the service resilience timeout. If the service limit on resilience timeout is smaller than the resilience timeout for the connecting client, the client uses the services limit as the resilience timeout.
The following figure shows some sample connections and resilience configurations in a domain with PowerCenter application services:
The following table describes the resilience timeout and the limits shown in the figure above:
Connect From
Connect To
Description
A
PowerCenter Integration Service
PowerCenter Repository Service
The PowerCenter Integration Service can spend up to 30 seconds to connect to the PowerCenter Repository Service, based on the domain resilience timeout. It is not bound by the PowerCenter Repository Service limit on resilience timeout of 60 seconds.
B
pmcmd
PowerCenter Integration Service
pmcmd
is bound by the PowerCenter Integration Service limit on resilience timeout of 180 seconds, and it cannot use the 200 second resilience timeout configured in INFA_CLIENT_RESILIENCE_TIMEOUT
.
C
PowerCenter Client
PowerCenter Repository Service
The PowerCenter Client is bound by the PowerCenter Repository Service limit on resilience timeout of 60 seconds. It cannot use the default resilience timeout of 180 seconds.
D
Node A
Node B
Node A can spend up to 90 seconds to connect to Node B. The Service Managers on Node A and Node B use the default node resilience timeout of 90 seconds.

0 COMMENTS

We’d like to hear from you!