Select the staging table that you want to configure.
The Staging Table Properties pane is displayed.
Select the
Enable delta detection
check box.
Select the
Detect deltas using specific columns
option.
A list of available columns is displayed.
Choose the columns that you want to use for delta detection and click
Add >
, or click
Add All >>
to add all the columns for delta detection.
When loading data to the staging table, if any column from the defined set has values different from the available previous load values, the row is treated as changed. If all columns from defined set are the same, the row is treated as unchanged. Columns that are not mapped are ignored.