Table of Contents

Search

  1. Preface
  2. Analyst Service
  3. Catalog Service
  4. Content Management Service
  5. Data Integration Service
  6. Data Integration Service Architecture
  7. Data Integration Service Management
  8. Data Integration Service Grid
  9. Data Integration Service Applications
  10. Interactive Data Preparation Service
  11. Enterprise Data Preparation Service
  12. Informatica Cluster Service
  13. Mass Ingestion Service
  14. Metadata Access Service
  15. Metadata Manager Service
  16. Model Repository Service
  17. PowerCenter Integration Service
  18. PowerCenter Integration Service Architecture
  19. High Availability for the PowerCenter Integration Service
  20. PowerCenter Repository Service
  21. PowerCenter Repository Management
  22. PowerExchange Listener Service
  23. PowerExchange Logger Service
  24. SAP BW Service
  25. Search Service
  26. System Services
  27. Test Data Manager Service
  28. Test Data Warehouse Service
  29. Web Services Hub
  30. Application Service Upgrade
  31. Appendix A: Application Service Databases
  32. Appendix B: Connecting to Databases from Windows
  33. Appendix C: Connecting to Databases
  34. Appendix D: Updating the DynamicSections Parameter of a DB2 Database

Safe Mode

Safe Mode

In safe mode, access to the PowerCenter Integration Service is limited. You can configure the PowerCenter Integration Service to run in safe mode or to fail over in safe mode:
  • Enable in safe mode. Enable the PowerCenter Integration Service in safe mode to perform migration or maintenance activities. When you enable the PowerCenter Integration Service in safe mode, you limit access to the PowerCenter Integration Service.
    When you enable a PowerCenter Integration Service in safe mode, you can choose to have the PowerCenter Integration Service complete, abort, or stop running workflows. In addition, the operating mode on failover also changes to safe.
  • Fail over in safe mode. Configure the PowerCenter Integration Service process to fail over in safe mode during migration or maintenance activities. When the PowerCenter Integration Service process fails over to a backup node, it restarts in safe mode and limits workflow activity and access to the PowerCenter Integration Service. The PowerCenter Integration Service restores the state of operations for any workflows that were running when the service process failed over, but does not fail over or automatically recover the workflows. You can manually recover the workflow.
    After the PowerCenter Integration Service fails over in safe mode during normal operations, you can correct the error that caused the PowerCenter Integration Service process to fail over and restart the service in normal mode.
The behavior of the PowerCenter Integration Service when it fails over in safe mode is the same as when you enable the PowerCenter Integration Service in safe mode. All scheduled workflows, including workflows scheduled to run continuously or start on service initialization, do not run. The PowerCenter Integration Service does not fail over schedules or workflows, does not automatically recover workflows, and does not recover client requests.

0 COMMENTS

We’d like to hear from you!