Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange Change Data Capture Introduction
  3. Part 2: CDC Components Configuration and Management
  4. Part 3: CDC Sources Configuration and Management
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: CDC for z/OS Troubleshooting
  8. Appendix B: DTL__CAPXTIMESTAMP Time Stamps

Stopping the Batch VSAM ECCR Interface

Stopping the Batch VSAM ECCR Interface

Stop the batch VSAM ECCR interface by using the PowerExchange Agent STOP command. This command disables the batch VSAM ECCR interface for the entire
z/OS
system. After the batch VSAM ECCR interface stops, PowerExchange does not capture changes for any VSAM data set that is subsequently opened. Change data capture activity that is in progress continues until the data sets are closed.
To stop the VSAM batch ECCR, enter the following command:
cmd_prefix
STOP VSAMECCR
The
cmd_prefix
variable is the command prefix for the PowerExchange Agent. You specify this prefix in the CmdPrefix statement in the PowerExchange Agent AGENTCTL parameters.
For more information about batch VSAM ECCR interface commands, see the
PowerExchange Command Reference
.