Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange Change Data Capture Introduction
  3. Part 2: CDC Components Configuration and Management
  4. Part 3: CDC Sources Configuration and Management
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: CDC for z/OS Troubleshooting
  8. Appendix B: DTL__CAPXTIMESTAMP Time Stamps

APF-Authorize the Libraries in the STEPLIB Concatenation

APF-Authorize the Libraries in the STEPLIB Concatenation

All libraries that are specified in the STEPLIB concatenation of the IMS log-based ECCR JCL must be APF-authorized.
  1. Verify that the PowerExchange LOAD and LOADLIB libraries are APF-authorized. You should have completed this step during installation.
  2. If you use the DTLCCIMX ECCR program that works with the DBRC API, APF-authorize the IMS RESLIB library, which must be included in the STEPLIB concatenation.
To determine the library names, see the ECCR JCL member, called
xxx
IMSEC, that PowerExchange generates in the PROCLIB library based on your entries in the
z/OS
Installation Assistant.