Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange Change Data Capture Introduction
  3. Part 2: CDC Components Configuration and Management
  4. Part 3: CDC Sources Configuration and Management
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: CDC for z/OS Troubleshooting
  8. Appendix B: DTL__CAPXTIMESTAMP Time Stamps

LOCAL_TIME Parameter

LOCAL_TIME Parameter

Optional. Controls whether the time stamps that the Datacom table-based ECCR uses to indicate when database changes occurred use the local time or Coordinated Universal Time (UTC) time.
ECCR time stamps indicate when changes were made in the database. They do not indicate when the ECCR captured the changes.
LOCAL_TIME={
N
|Y}
  • N
    . The ECCR time stamps use UTC time values based on the Datacom UTC time stamps in change records.
  • Y
    . The ECCR time stamps use local time values based on the Datacom SQL time stamps in the change records.
Default is N.